Lowest cost of ownership in nitrogen and protein determination
The rapid N exceed PLUS is a compact nitrogen and protein analyzer designed for laboratories that prioritize maximum cost efficiency without compromising analytical performance. Operating according to the safe, simple, and environmentally friendly Dumas method, it delivers fast and reliable nitrogen and protein determination in just 3–4 minutes per sample. Engineered for low cost of ownership, the analyzer uses CO₂ as a cost-efficient carrier gas and minimizes consumables consumption, resulting in the lowest cost per sample in its class. Despite its compact footprint, the instrument offers excellent detection sensitivity and maximum measurement accuracy for sample weights of up to 1.5 g / 1.5 ml. The ideal solution for laboratories seeking reliable nitrogen and protein analysis with minimal operating costs.
Highlights of the rapid N exceed PLUS
Lowest cost of ownership
Thanks to extended consumable uptime, operating costs are minimized without compromising analytical performance
Fast analysis
Analysis results are quickly available in just 3-4 minutes per sample
Easy to use
Smart workflows in the intuitive software, automatic system checks, and tool-free maintenance ensure simple operation
Reliable results - anytime
Matrix-independent calibration as well as optimized sample introduction and complete combustion of the whole sample always ensure highest precision and accuracy
Features
Lowest cost of ownership
The rapid N exceed PLUS is designed to minimize operating costs without compromising analytical performance. By using CO₂ as a cost-efficient carrier gas and reducing consumables consumption through advanced EAS REGAINER® technology and extended consumable uptime, the analyzer achieves an exceptionally low cost per sample. Combined with fast analysis times of up to four minutes and high measurement accuracy, laboratories benefit from reliable nitrogen and protein determination while keeping long-term operating costs to a minimum.
Fast analysis, fast results
The rapid N exceed PLUS realizes rapid nitrogen and protein determination in just 3–4 minutes per sample. Quick daily maintenance routines and less time-consuming calibration measurements significantly reduce setup time – saving you time every day and increasing throughput of real samples.
Easy to use
The rapid N exceed PLUS is designed for simple, reliable day-to-day operation. Improved process control and software with optimized navigation and smart workflows guide users efficiently through every step of the analysis. A status display directly on the instrument, automatic system checks, and integrated software assistants ensure quick preparation for analysis and smooth operation. Additionally, advanced EAS REGAINER® technology, extended consumable uptime and easy, tool-free replacement of pre-filled tubes simplify routine tasks. Using the Dumas combustion method eliminates the need for hazardous chemicals, making operation safer and more convenient for laboratory staff.
Reliable results - anytime
The rapid N exceed PLUS guarantees outstanding precision and accuracy through controlled oxygen jet-injection directly into the active zone and an industry-proven, catalytic post-combustion. This leads to matrix-independent results for even hard to digest samples. No need for time-consuming, frequent calibrations or expensive matrix-specific standards. All this results in reliably high data quality and a detection limit in the low ppm range.
Future-proof with a 10-year commercial guarantee
Thanks to the outstanding robustness and longevity of the rapid N exceed PLUS, we provide a 10-year commerical guarantee on the high-temperature combustion furnace and the thermal conductivity detector cell of the thermal conductivity detector (TCD). With our long-term oriented dedication to technical support, we provide spare parts for a minimum of 10 years. This results in outstanding low total cost of ownership, giving you confidence in return of investment.
Sample types

Product details
The rapid N exceed PLUS is optimized for the analysis of:
nitrogen
protein
Maximum sample weight
Up to 1.5 g
Element concentration range
Large concentration range:
N: up to 500 mg absolute, from ppm to 100 %
Precision
< 0.05 % absolute (250 mg aspartic acid), depending on sample type, analysis mode, and configuration
Analysis time
~ 3-4 min, depending on sample type
High-temperature combustion with 100 % recovery and detection of the released nitrogen. For nitrogen and protein “Dumas” analysis compliant with current ISO, EN, DIN, AOAC and other national and international standards.
Detector
Thermal Conductivity Detector (TCD)
Sample introduction
Sample introduction via integrated 60, 80*, or 120* positions autosampler, reloadable during analysis.
Maximum furnace temperature
1,200 °C
Instrument control
Windows® based rapid N exceed® PLUS operating software with LIMS integration and auto sleep and wake-up function for automated and unattended overnight operation. 21 CFR Part 11 functionality available. *
Required gases
carbon dioxide and oxygen
Dimensions
48 x 55 x 57 cm (W x D x H)
* optionally available
Electronic balance
Balance and elemental analyzer form a system. We offer analytical balances from the leading manufacturers with our instruments. Please contact usfor further information.
Sample former and pressing tools
For simplified sample preparation, we offer a manual tool for compressing samples in tin foil or cups, and a mechanical press for the preparation of pellets with paper wrapping.
Capsule sealing press
Tool for the exact dosing and gas-tight sealing of tin capsules for liquid samples.
Downloads